==polort rule of thumb==
 
==polort rule of thumb==
  

Revision as of 12:30, 9 July 2008

polort rule of thumb

AFNI folks suggest that for every 150 seconds you should add a degree to the polynomial.

For a 150 second long scan, you would use -polort 1, for a 300 second scan, you would use -polort 2, and so forth.

3dRegAna

3dRegAna is an AFNI program which can be used to do multiple linear analysis

-model tag

The -model tag can be used to specifiy and test regression model

 -model 1 : 0

will test Yi = B0 + B1X1i+ei vs. Yi = B0 + ei

 -model 2 : 0

will test Yi = B0 + B2X2i+ei vs. Yi = B0 + ei

 -model 2 : 1 0

will test Yi = B0 + B1X1i + B2X2i+ei vs. Yi = B0+ B1X1i + ei

 -model 2 1 : 0