BACK TO LIST

Fig. 1. Experimental (symbols) and simulated (lines) laminar flame speed of JP-10 in air at 403 K unburned gas temperature and 1 atm pressure. The error bars represent ±2σ data uncertainties. Data are taken from [1].

 

Fig. 2. Experimental (symbols) and simulated (lines) laminar flame speed of JP-10 in O2 at an equivalence ratio of 0.9 (top panel) and 1.05 (bottom panel) with N2 and He as the diluent gas at elevated pressures. The temperature values given in the plots are the unburned gas temperatures at the corresponding pressures. The error bars represent ±2σ data uncertainties. Data are taken from [1].

Reference

[1]  Y. Tao, R. Xu, K. Wang, J. Shao, S.E. Johnson, A. Movaghar, X. Han, J. Park, T. Lu, K. Brezinsky, F.N. Egolfopoulos, D.F. Davidson, R.K. Hanson, C.T. Bowman, H. Wang, A physics-based approach to modeling real-fuel combustion chemistry - III. Reaction kinetic model of JP10, Combustion and Flame 198 (2018) 466–476.